Brand Name : Green Spring

Model Number : LSY-30001

Certification : ISO13485,ISO9001

Place of Origin : China

MOQ : 1kit

Price : Negotiable

Payment Terms : T/T

Supply Ability : 100000 tests per day

Delivery Time : 7~14days

Key words : Porcine Toxoplasmosis IgG Antibody ELISA Test Kit

Sample Performance : Porcine serum

Specification : 192 Wells/Kit

Shelf Life : 12 months

Storage : at 2-8 ℃, don’t expose in strong light, not freeze.

Type : Porcine Test Kit

Contact Now

Porcine Toxoplasmosis IgG Antibody ELISA Test Kit 192 Wells/Kit

1. Usage


Porcine Toxoplasmosis IgG antibody test kit is used for the detection of the Toxoplasmosis antibodies in porcine serum.

2. Principle


The test kit is enzyme immunoassay for the detection toxoplasmosis antibodies in porcine serum. Toxoplasmosis antigens are coated on 96-well plate, add sample into wells and then antibodies bound specifically by antigens, the unbound antibodies and other components will be removed by washing. Next add enzyme conjugation to specifically bind with the compound of antibodies and antigens on the microplate. The unbound enzyme conjugation will be removed by washing. Add the TMB substrate in the well, react to a blue product. At last, end the reaction by adding stop solution.

3. Components

1 TOX antigencoated microplate 96T X 2
2 Enzyme conjugate 22ml yellow lid
3 Sample diluent solution 50ml transparent lid
4 TOX-IgG Negativecontrol serum 1.5ml green lid
5 TOX-IgG Positivecontrol serum 1.5ml red lid
6 Substrate 12ml X2 orange lid
7 Stop solution 12ml blue lid
8 20×concentrated washing buffer 50ml white lid
9 Adhesive Foil 2 pieces
10 Instruction 1 piece

4. Material Required not Provided


1) Microplate Reader (Dual-wave length: 450/630 nm).
2) Microplate Washer.
3) Micropipettes, adjustable (Single-wave length 1-100ul,0.5-10ul,multi-wave length 30-300ul).
4) Constant temperature box or water bath box.
5) Oscillator.
6) Disposable tips (10ul, 200ul)
7) Deionized water

5. Solution preparation


1) Sample dilute: Dilute sample with the sample diluent solution at 40 times.(for example: 117ul sample diluent solution + 3ul serum), the negative control and positive control serum do not need to dilute.
2) Washing solution preparation: return 20×concentrated washing buffer into room temperature before use and shake until crystallization dissolved completely, then dilute the 20×concentrated washing buffer with distilled water or deionized water at 20 times (for example: 10ml 20×concentrated washing buffer + 190ml distilled water).


6. Procedure


1) Adding sample: Take out the required coated plates according to sample quantity (Can be detached) and record the sample position on a worksheet. Set 2 wells for negative control serum and 2 wells for positive control serum, add undiluted negative and positive control serum to its well accordingly, 100 μL/well. Others are wells for samples, add 100μL/well of the diluted sample.
2) Mix gently for 30s, incubate at 37℃ for 30 min.
3) Remove adhesive foil. Pour the liquid out of the wells, add Washing solution into each well fully, stand for 10s. Repeat 3 times, at last time pat to dry on absorbent paper.
4) Add 100 μL enzyme conjugate into each well, cover plate with new adhesive foil.Incubate at 37 ℃ for30 min.
5) Repeat step 3(washing).
6) Add 100μL substrate into each well, mix properly,incubate for 10 min at 37 ℃ in the dark with new adhesive foil.
7) Add 50μL stop solution into each well, mix gently and determine the result within 10 min.

7. Results


Cut-Off Value (COV) = Negative control average OD value X 2.1 (calculate as 0.08 when Negative control OD value is less than 0.08 )
Generally speaking, the TOX-IgG Positive control average OD value should be greater than or equal to 0.60, the TOX-IgG Negative control average OD value should be less than 0.15, otherwise the test is invalid, need to retest.
If the sample OD value≥2COV, the sample is classified as POSITIVE for TOX-IgG antibodies;
If If the sample OD value<COV, the sample is classified as NEGATIVE for TOX-IgG antibodies.
If between positive and negative control value, it is skeptical.

8.Product performance


1. Specificity: to test 30 negative control serums, no false positive.
2. Sensitivity: to test 30 positive control serums, no negative.
3. Precision: CV(%)no bigger than 15%(n=10)
4. Stability: Store at 2℃~8℃ for 12 months or store at 37℃ for 3 days, the result can reach the above 3 standards.

9. Precautions and warnings for users


1. This test kit is suitable for in vitro diagnostics.
2. Wear glove and working clothes when operate, treat the test kit as containing infectious material.
3. Experiment rubbish should be dealt with high pressure steam sterilization at 121 ℃ for 30 minutes, or treated with 5.0g/L sodium hypochlorite disinfectant for 30 minutes, then discard.
4. MicroWell plate removed from the refrigerated environment should be balanced moisture to dry at room temperature, then can be opened. Put back unused MicroWell plate into dry foil bag and sealed at 4 ℃. Unused liquid reagent should cover caps, store at 2-8 ℃ in dark with other group components.
5. If the 20×concentrated washing buffer appears crystal, it is normal, put at 37℃until been dissolved.
6. Should use Micropipettor to add sample and reagents, and often proof its accuracy.
7. When adding washing buffer, should be full but no overflow, avoid appearing free enzyme at mouth of well or cross pollution between wells.
8. Stop solution is corrosive, use large amount of water to wash immediately when touch the skin or clothes.

Specifications:96 wells × 2.
Expiry date:12 months.
Storage: at 2-8 ℃, don’t expose in strong light, not freeze.
Production Date:On outer-packing of the test kit.

Porcine Toxoplasma Rapid Test Kit Toxoplasma IgG ELISA Antibody Test Kit 192 Wells/Kit

Q1: How long will it take for you to ship?
A1: Usually ships within 7 working days.

Q2: Do you support OEM/ODM?
A2: can be supported. We can customize according to your specific needs and specific quantities.

Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 certification and ISO13485 certification, so far all the production process, we have standard rules, we comply with the relevant behavior and laws of the government.

Q4: Is after-sales service guaranteed?
A4: We provide professional online technical after-sales service. If the product fails during the experiment, we can provide
one-to-one guidance through telephone, video and other forms.

Q5: What is your minimum order quantity?
A5: 1Kit.

Q6: What is the shipping method?
A6: Usually by air, we will choose the best shipping method for you, and we can also ship according to the shipping method you require.


Product Tags:

Porcine toxoplasma rapid test kit

      

serum toxoplasma rapid test kit

      

ELISA Antibody toxoplasma igg elisa

      
China Porcine Toxoplasma Rapid Test Kit Toxoplasma IgG ELISA Antibody Test Kit 192 Wells/Kit wholesale

Porcine Toxoplasma Rapid Test Kit Toxoplasma IgG ELISA Antibody Test Kit 192 Wells/Kit Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Wensidun Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)